Jiaxing Doublewin Cable Co., Ltd. yog ib qho ntawm feem txhim khu kev qha manufacturers thiab lwm tus neeg ntawm cat6 ethernet cable nyob rau hauv Suav teb. Yog tias koj yuav mus rau cov lag luam wholesale bulk cat6 ethernet cable ua nyob rau hauv Suav teb, txais tos kom tau txais pricelist thiab cov qauv dawb los ntawm peb lub hoobkas. Tag nrho cov customized cables yog nrog cov khoom zoo thiab cov nqi sib tw.
Cat6 Ethernet Cable (tseem hu ua Cat6 LAN cable) yog ib qho kev ua haujlwm siab sib tw-pair network cable rau kev teeb tsa sab hauv tsev. Nws nta 4 khub ntawm twisted khoom tooj liab conductors, HDPE rwb thaiv tsev thiab tus ntoo khaub lig separator kom txo tau crosstalk. Nws xa 250MHz bandwidth, txhawb kev ruaj khov 1Gbps kis mus txog 100 meters thiab luv-ntau 10Gbps networking. Peb tsim UTP, FTP thiab SFTP Cat6 ethernet cable. Cov tsho sab nrauv muaj xws li PVC rau kev siv sab hauv tsev thiab LSZH rau cov pa luam yeeb tsawg, hluav taws kub-kev ruaj ntseg hauv tsev. Qhov no cable yog dav siv nyob rau hauv chaw ua hauj lwm tes hauj lwm, IP koob yees duab soj ntsuam, coj mus muag tsev thaiv thiab cov ntaub ntawv kev sib txuas lus systems.
Raws li ib tug kws tshaj lij cable chaw tsim tshuaj paus, peb muab bulk reels, kev cai cable luam ntawv thiab OEMntim rau distributors, system integrators thiab enginenplhaib cov neeg cog lus thoob ntiaj teb.
Cov yam ntxwv tseem ceeb
• 250MHz bandwidth, txhawb Gigabit Ethernet
• Khoom liab qab tooj liab tus neeg xyuas pib rau kev ruaj ntseg teeb liab kis tau tus mob
• Integrated crosstalk kom txo tau qhov ze-kawg crosstalk
• Ntau yam kev tsim kho: UTP / FTP / SFTP muaj
• PVC lossis LSZH txheej txheej rau cov haujlwm sab hauv tsev sib txawv
• RoHS ua raws, ua haujlwm ntev rau kev teeb tsa hauv phab ntsa

Cat6 Ethernet Cable Technical Specifications
Cat6 Ethernet Cables xa 250 MHz bandwidth thiab 1 Gbps ceev, muaj nyob rau hauv U / UTP, F / UTP thiab SF / UTP rau txhua qhov txuas sab hauv.
| Khoom npe | Cat6 Ethernet Cable |
|---|---|
| AWG | 23 AWG los yog kev cai |
| Cov khoom siv coj ua | CU / CCA |
| Hlau Dia | 0.56 / 0.58 hli |
| Ntaub thaiv npog | UTP / FTP / SFTP |
| Jacket Khoom | 1. PVC Jacket rau Cat6 sab hauv tsev cable 2. PE Ib lub tsho rau Cat6 sab nraum zoov cable 3. PVC + PE ob lub tsho Cat6 sab nraum zoov cable |
| Xim | Cov xim sib txawv muaj |
| Ua haujlwm kub | -20℃- +75 degree |
| Daim ntawv pov thawj | CE/ROHS/ISO9001 |
| Kev ntsuas hluav taws | CMP / CMR / CM / CMG / CMX |
| Daim ntawv thov | PC / ADSL / Network Module Phaj / Phab ntsa qhov (socket) / thiab lwm yam |
| Pob | 1000ft 305m ib yob, lossis kev cai |
| Marking On Jacket | Kev cai |
| Qauv | Daim ntawv thov | Main Performance | Cov yam ntxwv ntawm tus qauv | Sheath Material |
|
Cat6 U/UTP Sab hauv |
Sab hauv kab rov tav cabling, LAN thaiv | 250MHz bandwidth, 1000Mbps, txhawb txog li 5GBASE-T | 23AWG oxygen-dawb tooj liab, nruab nrab ntoo khaub lig separator, optimized crosstalk | PVC / LSZH yeem |
|
Cat6 F/UTP Sab hauv |
Sab hauv cabling, nruab nrab los tiv thaiv kev cuam tshuam | 250MHz bandwidth, 1000Mbps | Aluminium foil shielding + 23AWG tooj liab conductor, txhim khu kev qha hluav taws xob | PVC / LOJ |
| Cat 6 SF / UTP Sab Hauv Tsev | Sab hauv cabling, siab EMI ib puag ncig | 250MHz bandwidth, 1000Mbps, muaj zog tiv thaiv kev cuam tshuam | Ob chav shielding (txhuas ntawv ci + braid), 23AWG tooj liab | PVC / LOJ |
| Cat 6 U/UTP Sab nraum zoov | Sab nraum zoov LAN thaiv, nyiaj siv ua haujlwm, phab ntsa mounting | 100MHz bandwidth, 1000Mbps | 23AWG tooj liab, central cross separator, unshielded | PE lub tsho sab nrauv, waterproof & UV-resistant |
| Cat 6 F / UTP Sab nraum zoov | Sab nraum zoov cable, tiv thaiv EMI | 250MHz bandwidth, 1000Mbps | Ib qho txhuas ntawv ci shielding, 23AWG tooj liab neeg xyuas pib | PE + PVC ob txheej txheej |
| Cat 6 SF / UTP Sab nraum zoov | Sab nraum zoov cuam tshuam ib puag ncig | 250MHz bandwidth, 1000Mbps | Muab ob npaug rau shielding (foil + braid), siab EMI tsis kam | PE + PVC ob chav sheath, weatherproof |




Cat6 Ethernet Cable - Qhov Chaw Qab Zib rau Cov Kab Ntsig Tshiab
Nug txhua tus cabling installer dab tsi lawv muab tso rau hauv lub tsev tshiab thiab cov lus teb yogCat6 Ethernet cable. Ntawm 250 MHz nws muaj ob zaug bandwidth ntawm Cat5e, tuav Gigabit Ethernet nrog lub taub hau dav dav, txhawb nqa PoE thiab PoE + yam tsis muaj teeb meem cua sov, thiab zam cov Cat6a tus nqi hwm uas feem ntau cov chaw ua haujlwm tsis xav tau. Cat6 yog qeb yam tsawg kawg nkaus uas pom zoo los ntawm BICSI, lub koom haum ua haujlwm cabling, thiab yog qhov chaw qab zib uas qhov kev ua tau zoo, tus nqi thiab kev pov thawj yav tom ntej. Nplooj ntawv no muab cov lej ua haujlwm rau koj, kev xaiv tiv thaiv, qib kev teeb tsa, thiab Cat6 piv rau Cat5e thiab Cat6a li cas - yog li koj tuaj yeem qhia meej nrog kev ntseeg siab.
250 MHz
Ob zaug bandwidth ntawm Cat5e (100 MHz).
1 Gbps · 100 m
Gigabit Ethernet nrog lub taub hau dav dav.
PoE / PoE +
30 W rau ib qhov chaw nres nkoj - Wi-Fi APs, IP koob yees duab.
UTP Txuj
Unshielded yog txaus rau feem ntau cov chaw ua haujlwm.
CM / CMR / CMP
Txhua qib kev teeb tsa muaj.
Ntiaj teb no Standards
TIA/EIA-568-B.2-5, ISO/IEC 11801 Class E.
Cat6 vs Cat5e vs Cat6a - Vim li cas Cat6 Yog Qhov Qab Zib
Peb feem ntau cov qauv cabling pawg zaum ntawm tus nqi / kev ua haujlwm nkhaus. Cat6 thaj av raws nraim qhov chaw ua haujlwm tshiab feem ntau yuav tsum yog: txaus bandwidth thiab headroom yam tsis tau them 10 Gbps uas feem ntau cov chaw ua haujlwm yuav tsis siv rau kaum xyoo.
Cat5 e
1 Gbps
100 MHz bandwidth
100 m · PoE + max
• Kev xaiv pheej yig tshaj
• Tsis muaj headroom saum Gigabit
• Cov nyiaj rov qab tsuas yog siv nyiaj xwb
Cat6 ★
1 Gbps
250 MHz bandwidth
100 m · PoE + npaj
• 2 × Cat5e bandwidth
• Qhov zoo tshaj plaws headroom/tus nqi piv
• BICSI pom zoo yam tsawg kawg nkaus
Cat6A
10 Gbps
500 MHz bandwidth
100 m · PoE++ npaj
• 10 × cov ntaub ntawv tus nqi vs Cat6
• 50–70% tus nqi them nqi
• Cov chaw khaws ntaub ntawv, kev pov thawj yav tom ntej
| Parameter | Cat5 e | Cat6 | Cat6A |
|---|---|---|---|
| Bandwidth | 100 MHz | 250 MHz | 500 MHz |
| Max cov ntaub ntawv tus nqi | 1 Gbps | 1 Gbps + headroom | 10 Gbps |
| Max channel ntev | 100 m | 100 m | 100 m |
| Tus coj | 24 AWG | 23 or 24 AWG | 23 AWG |
| Tom ntej: 250 MHz | Tsis tau teev tseg | Ntau dua lossis sib npaug rau 38.3 dB | Ntau dua lossis sib npaug rau 38.3 dB |
| ACR @ 250 MHz | Tsis tau teev tseg | Ntau dua lossis sib npaug rau 17.8 dB | Ntau dua lossis sib npaug rau 18.0 dB |
| Insertion poob @ 250 MHz | Tsis tau teev tseg | Tsawg dua lossis sib npaug li 21.4 dB | Tsawg dua lossis sib npaug li 20.7 dB |
| PoE | PoE & PoE + | PoE & PoE + | PoE & PoE + & PoE ++ |
| Tus nqi txheeb ze | 100% | ~120% | ~180% |
Txoj cai ntawm tus ntiv tes xoo
• Cov peev nyiaj rov qab siv dua, uas twb muaj lawm Cat5 khiav→ Cat5e tsuas yog tias koj yuav tsum
• Tshiab chaw ua hauj lwm nruab, zoo tshaj headroom / nqi → Cat6 (yam tsawg kawg pom zoo)
• Data center, PoE++, 10 Gbps yav tom ntej→ Cat6a
• Txuag 50-70% vs Cat6Athiab tseem tau txais 250 MHz headroom nrog Cat6
Cat6 Ethernet Cable - UTP, FTP lossis SFTP?
Cat6 Ethernet cable tsis xav tau kev tiv thaiv kom tau raws li nws qhov kev ua tau zoo 250 MHz - tsis zoo li Cat7 thiab Cat8, uas ib txwm muaj kev tiv thaiv. Tab sis kev tiv thaiv tseem muaj qhov chaw uas muaj kev cuam tshuam electromagnetic (EMI) tam sim no.
| Hom | Qauv | Kev tsis lees paub EMI | Thaum siv |
|---|---|---|---|
| UTP | 4 khub twisted, tsis muaj ntaub thaiv npog | Tsawg | Standard chaw ua hauj lwm, tsev kawm ntawv, feem ntau nyob rau hauv tsev installation |
| FTP | Al foil zuag qhia tag nrho + tinned Cu ntws hlau | Nruab nrab | Nyob ze fais fab cables, machinery, tshaj tawm, HVAC motors |
| SFTP | Al foil + tinned Cu braid shield | Siab | Muaj, siab EMI, cov chaw zov me nyuam nrog lub zog ceev |
Qhov tseem ceeb - Shield grounding
Ib daim thaiv tsuas ua haujlwm yog tias nws yog hauv avib kawg nkaus xwb(feem ntau yog thaj vaj huam sib luag / hloov kawg). Grounding ntawm ob qhov kawg tsim ib lub voj hauv av uas tshem tawm qhov thaiv. Tag nrho peb cov FTP thiab SFTP Cat6 Ethernet cables tuaj nrog tinned tooj liab xaim rau hauv av kom zoo.

Koj Hom ntawm Cat6 Reel
Kev cai lub tsho xim, luam tawm lus dab neeg, ntev, ntim. RJ45 thaj qaum sib dhos ntawm kev thov. NDA-tiv thaiv ntiag tug-label SKUs.
RFQ & Feasibility
Xa spec, ntim, lo lus uas peb. Kev ua tau zoo, MOQ thiab tus nqi hauv 12 teev ua haujlwm.
Kev Cai Qauv
Custom-printed qauv nyob rau hauv koj hom xim rau koj pab neeg txiav txim kom validate.
Production & QC
20-25 hnub ua haujlwm. Cov duab nce qib ntawm tooj liab kos, spline insert, sheath, kawg xeem.
Test, Pob & Nkoj
100% kev kuaj hluav taws xob, cov khoom xa tawm, cov ntaub ntawv (CI / PL / B / L / C / O / RoHS). Nkoj Shanghai / Ningbo.
Cim npe nrov: Tuam Tshoj cat6 ethernet cable manufacturers, lwm tus neeg, Hoobkas